Error Items |
LED |
TROUBLE |
TESTING |
I/M-SENSOR (R on Twin I/M units) | Ice Maker Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F | The voltage at MAIN PCB Sensor between 4.5V~1.0V | |
R-SENSOR | Refrigerator Room Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. | The voltage at MAIN PCB Sensor between 4.5V~1.0V | |
DEFROST SENSOR OF R ROOM | Ref. Defrost Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. | The voltage at MAIN PCB Sensor between 4.5V~1.0V | |
R-FAN ERROR | This error indicates the Refrigerator Evap Fan is not spinning at the correct RPM or the fan feedback line is open. | Fan voltage at MAIN PCB shall be between 7V~12V | |
I/M FUNCTION ERROR(R on Twin I/M) | This error indicates the Ice tray has not returned to level after an ice harvest. The error is displayed after three failed attempts. | Replace I/M | |
R-DEFROSTING ERROR | Refrigerator Room defrost heater- open or short-circuit, connector failure, or defective temperature fuse/bi-metal. Defrost on over 80 minutes. | Disconnect defrost connector from PCB, check resistance | |
PANTRY-DAMPER HEATER ERROR | Sensor system in Pantry Room errors. | Disconnect heater connector from PCB, check resistance. | |
PANTRY-SENSOR ERROR | CR Room Sensor Error- This can be an open or short-circuit, contact failure. Cause is also a temperature reading > 122°or < -58 ° F. | The voltage of MAIN PCB Sensor between 4.5V~1.0V | |
WATER HEATER ERROR | Error is displayed when the water reservoir tank heater is open or shorted. Disconnect heater connector from PCB, check resistance. | Disconnect heater connector from PCB, check resistance. | |
EXT-SENSOR | Ambient Temp. Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. | The voltage at MAIN PCB Sensor between 4.5V~1.0V | |
F-SENSOR | Freezer Compartment Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. | The voltage at MAIN PCB Sensor between 4.5V~1.0V | |
F-DEF-SENSOR | Freezer Room Defrost Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. | The voltage at MAIN PCB Sensor between 4.5V~1.0V | |
F-FAN ERROR | This error indicates the Freezer Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. | Fan voltage at MAIN PCB shall be between 7V~12V | |
C-FAN ERROR | This error indicates the Condenser Fan is not spinning at the correct RPM or the fan feedback line is open. | Fan voltage at MAIN PCB shall be between 7V~12V | |
FRENCH DOOR ICE ROOM SENSOR | Ice Room Sensor Error- open or short-circuit, connector failure. Cause is also a temperature reading > 122°or < -58 ° F. | The voltage at MAIN PCB Sensor between 4.5V~1.0V | |
F-DEFROSTING ERROR | Freezer defrosting heater- open or short-circuit, connector failure, or defective temperature fuse/bi-metal. Defrost on for over 80 minutes. | Disconnect defrost connector from PCB, check resistance. | |
FRENCH DOOR ICE ROOM FAN ERROR | This error indicates the Ice Room Compartment Evap. Fan is not spinning at the correct RPM or the fan feedback line is open. | Fan voltage at MAIN PCB shall be between 7V~12V | |
Uart ERROR COMMUNICATION | This error is not applicable, if the error is detected during diagnostic testing please ignore it. | No Repair Necessary | |
L.M ERROR COMMUNICATION | Communication error within the Main PCB | Replace main PCB | |
P.M ERROR COMMUNICATION | Communication between the Main PCB and Keypad. | Check wiring in door & cabinet, Panel PCB, Main PCB |